The ignition switch supplies Ignition 1 voltage to the inflatable restraint sensing and diagnostic module (SDM) at terminal A1 using the AIR BAG fuse. The ignition switch also supplies Ignition 1 voltage to the AIR BAG warning indicator using the IG fuse. The AIR BAG warning indicator is connected to the AIR BAG indicator control terminal A9 of the SDM. When the ignition switch is first turned to the ON position, the SDM responds by flashing the AIR BAG warning indicator seven times. If Ignition 1 is outside of the normal operating voltage range (9.0 volts-16.0 volts) for more than 25 ms, the AIR BAG warning indicator will come ON solid with no DTCs set.
In order to disable the shorting bar from terminal A9 to terminal A18 inside the inflatable restraint sensing and diagnostic module (SDM) wiring harness connector, the following two conditions must be met:
• | The SDM wiring harness connector must be properly connected to the SDM. |
• | The connector position assurance (CPA) must be properly installed in the SDM wiring harness connector. |
When measurements are requested in this table, use the J 39200 DMM with the correct terminal adapter from the J 35616 Connector Test Adapter Kit. When an inspection for proper connection is requested, refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems. When a wire, connector or terminal repair is requested, use the J-38125 Terminal Repair Kit and refer to Wiring Repairs in Wiring Systems.
The numbers below refer to the step numbers on the diagnostic table:
This step checks to see if the scan tool can communicate with the inflatable restraint sensing and diagnostic module (SDM).
This step checks to see if sufficient igntion voltage is applied to the SDM.
This step checks to see if excessive ignition voltage is applied to the SDM.
This step checks to see if the retainer assembly or the shorting bar is damaged or corroded.
This step checks to see if the SDM wiring harness connector terminals are damaged or corroded.
This step checks to see if the SDM terminals are damaged or corroded or if the lifting tab on the SDM is damaged.
This step checks to see if the SDM wiring harness connector properly connects to the SDM and if the connector position assurance (CPA) is properly installed.
This step checks to see if there is a short to ground in the AIR BAG warning indicator control circuit.
This step determines if there is a short between the AIR BAG warning indicator control circuit and the SDM ground circuit or if there is a short to ground in the AIR BAG warning indicator control circuit.
This step checks to see if the AIR BAG fuse is not open. An open SIR Fuse would cause the AIR BAG warning indicator to come ON steady.
This step checks to see if a short to ground caused the AIR BAG fuse to open.
This step checks for a short to ground in AIR BAG fuse feed circuit.
This step checks to see if the SDM wiring harness connector properly secures to the SDM.
This step checks to see if there is an open in AIR BAG fuse feed circuit.
This step determines if there is an open or a high resistance condition in the B+ feed circuit to the input side of the AIR BAG fuse or if there is a malfunctioning SDM.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the SIR Diagnostic System Check performed? | -- | ||
Does the scan tool communicate with the SDM? | -- | Go to Scan Tool Does Not Communicate with SDM | ||
Use the scan tool to request the SIR scan tool data display. Is the ignition voltage more than the specified value? | 9.0 V | |||
Is the ignition voltage more than the specified value? | 16.0 V | Go to Battery Is Undercharged or Overcharged in Engine Electrical | ||
Is the retainer assembly or the shorting bar damaged or corroded? | -- | |||
6 |
Is the repair complete? | -- | -- | |
Carefully inspect the SDM wiring harness connector for corrosion or damaged terminals. Are the SDM wiring harness connector terminals damaged or corroded? | -- | |||
8 | Replace the damaged or corroded SDM wiring harness connector terminals. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
Important: Properly inspect the SDM terminals and the shorting bar lifting tab in order to avoid misdiagnosis. Are the SDM terminals damaged or corroded or is the shorting bar lifting tab damaged? | -- | |||
Does the SDM wiring harness connector properly connect to the SDM and is the CPA properly installed? | -- | |||
11 | Replace the SDM wiring harness connector. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
12 |
Does the air bag warning indicator come ON steady? | -- | ||
Is the measured resistance less than the specified value? | OL | |||
Is the resistance reading less than the specified value? | OL | |||
15 | Locate and repair a short to ground in the AIR BAG indicator control circuit. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
16 |
Is the repair complete? | -- | -- | |
17 | Replace the instrument cluster. Refer to Instrument Cluster Replacement in Instrument Panel, Gauges and Console. Is the repair complete? | -- | -- | |
Is the AIR BAG fuse open? | -- | |||
Is the AIR BAG fuse open? | -- | |||
Is the measured resistance less than the specified value? | OL | |||
21 |
Is the repair complete? | -- | -- | |
22 | Install the AIR BAG fuse. Is the repair complete? | -- | -- | |
Inspect the SDM wiring harness connector. Refer to Inflatable Restraint Sensing and Diagnostic Module Replacement . Is the connector secure? | -- | |||
24 |
Is the repair complete? | -- | -- | |
25 |
Is the SDM wiring harness connector terminal A1 damaged or corroded? | -- | ||
26 | Replace the SDM wiring harness connector. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
27 | Inspect the SDM terminals for damage or corrosion. Are any terminals damaged or corroded? | -- | ||
28 | Replace the SDM. Refer to Inflatable Restraint Sensing and Diagnostic Module Replacement . Is the repair complete? | -- | -- | |
Use the J 39200 to measure the resistance between the output side of the AIR BAG fuse and terminal A1 of the SDM wiring harness connector. Is the measured resistance within the specified value? | 0-2 ohms | |||
30 | Locate and repair an open or a high resistance condition in the ignition voltage feed circuit to the SDM. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
Is the measured voltage within the specified value? | B+ | Go to Power Distribution Schematics in Wiring Systems | ||
32 |
Have all the SIR components been reconnected and properly mounted? | -- | -- |