Removal Procedure
- Discharge and recover
the refrigerant. Refer to Refrigerant Recovery and Recharging
.
- Remove the grill. Refer to
Grille Replacement
in Exterior Trim.
- Disconnect the A/C refrigerant pressure switch electrical connector (1).
- Remove the A/C refrigerant pressure switch from the condenser
outlet line. Use a second wrench to hold the line.
Installation Procedure
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the A/C
refrigerant pressure switch to the condenser outlet line. Use a second wrench
to hold the line.
Tighten
Tighten the switch to 18 N·m (13 lb ft).
- Connect the A/C refrigerant pressure switch electrical connector (1).
- Install the grill. Refer to
Grille Replacement
in Exterior Trim.
- Evacuate and recharge the air conditioning system. Refer to Refrigerant Recovery and Recharging
.
- Operate the A/C system and inspect for refrigerant leaks. Refer
to Leak Testing
.