Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Exterior Lights Schematics | |||
1 | Did you review the Lighting System Description and Operation and perform the necessary inspections? | Go to Step 2 | |
2 | Verify that the back up lamps are always on. Does the system operate normally? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Do the backup lamps illuminate? | Go to Step 4 | Go to Step 5 |
4 | Adjust/replace the park/neutral position switch. Refer to Park/Neutral Position Switch Replacement in Automatic Transmission - 35 Speed - MB3. Did you complete the repair? | Go to Step 8 | -- |
5 |
Do the backup lamps illuminate? | Go to Step 6 | Go to Step 7 |
6 | Replace the backup lamp switch. Did you complete the repair? | Go to Step 8 | -- |
7 | Repair a short to B+ on the backup lamp feed circuit between the backup lamp switch and the SP450. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |