Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics | |||
1 | Did you review the Air Delivery Description and Operation and the Air Temperature Description and Operation perform the necessary inspections? | Go to Step 2 | |
2 | Operate the blower motor at each speed. Does the blower motor operate at any speed? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the test lamp light? | Go to Step 11 | Go to Step 4 |
4 | Test the blower motor supply voltage circuit for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 15 | Go to Step 5 |
5 | Test the ground circuit between the blower motor and S200 for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 15 | Go to Step 6 |
6 | Test that the HTR relay is open between terminals 4 and 5 and that there is continuity between terminals 4 and 2. Refer to Fuse and Relay Block 3 in Wiring Systems. Did the relay test OK? | Go to Step 7 | Go to Step 12 |
7 | Test the HTR relay coil supply voltage circuit for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 15 | Go to Step 8 |
8 | Test the HTR relay control circuit for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 15 | Go to Step 9 |
9 | Test the blower switch ground circuit for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 15 | Go to Step 10 |
10 | Test the blower switch for a high resistance or an open. Refer to Circuit Testing in Wiring Systems and Blower Switch Replacement . Did you find and correct the condition? | Go to Step 15 | -- |
11 | Inspect for a poor connection at the harness connector of the blower motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 15 | Go to Step 13 |
12 | Inspect for a poor connection at the harness connector of the heater relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 15 | Go to Step 14 |
13 | Replace the blower motor. Refer to Blower Motor Replacement . Did you complete the replacement? | Go to Step 15 | -- |
14 | Replace the heater relay. Refer to Blower Motor Relay Replacement . Did you complete the replacement? | Go to Step 15 | -- |
15 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |