GM Service Manual Online
For 1990-2009 cars only

Step

Action

Yes

No

1

Did you perform the Heater Blower Controls System Check?

Go to Step 2

Go to Heater Blower Controls System Check

2

Remove the HTR relay from fuse and relay block 3.

Does the blower motor run?

Go to Step 3

Go to Step 4

3

Repair the short to voltage in the BLK wire between fuse and relay block 3 and the blower motor. Refer to Wiring Repairs in Wiring Systems.

Is the repair complete?

Go to Heater Blower Controls System Check

--

4

Test that the HTR relay is open between terminals 4 and 5 and that there is continuity between terminals 4 and 2. Refer to Fuse and Relay Block 3 .

Did the relay test OK?

Go to Step 5

Go to Step 6

5

  1. Turn the blower speed selector switch to the OFF position.
  2. Test for a short to ground in the BLU/ORN wire between fuse relay 3 and blower speed selector switch.

Was a short found?

Go to Step 7

Go to Step 8

6

Replace the HTR relay. Refer to Blower Motor Relay Replacement .

Is the repair complete?

Go to Heater Blower Controls System Check

--

7

Repair the short. Refer to Wiring Repairs in Wiring Systems.

Is the repair complete?

Go to Heater Blower Controls System Check

--

8

Replace the blower speed selector switch. Refer to Blower Switch Replacement .

Is the repair complete?

Go to Heater Blower Controls System Check

--