Removal Procedure
- Remove the case side cover. Refer to
Control Valve Body Cover Replacement
.
- Disconnect the transaxle wiring harness.
Notice: Do NOT remove the three bolts which hold the pump together.
- Remove the oil pump bolts (205, 206, 207).
- Remove the oil pump (200) from the valve body (300).
- Inspect the oil pump. Refer to
Transmission Fluid Pump Assemble
in Transmission/Transaxle/Transfer Case 4T65-E Unit Repair Manual.
Installation Procedure
- Install the oil pump (200) to the valve body (300).
Notice: Refer to Fastener Notice in the Preface section.
- Install the oil pump bolts (205, 206, 207).
Tighten
• | Tighten the M6 X 1.0 X 20 bolt (205) to 8 N·m (70 lb in). |
• | Tighten the M6 X 1.0 X 85 bolt (207) to 12 N·m (106 lb in). |
• | Tighten the M6 X 1.0 X 95 bolt (206) to 16 N·m (12 lb ft). |
- Connect the transaxle wiring harness.
- Install the case side cover. Refer to
Control Valve Body Cover Replacement
.
Important: It is recommended that transmission adaptive pressure (TAP) information be reset.
Resetting the TAP values using a scan tool will erase all learned values in all cells. As a result, The ECM, PCM or TCM will
need to relearn TAP values. Transmission performance may be affected as new TAP values are learned.
- Reset the TAP values. Refer to
Adapt Function
.