• | J 39400-A Halogen Leak Detector |
• | J 38185 Hose Clamp Pliers |
Caution: Refer to Battery Disconnect Caution in the Preface section.
35.1. | Pull the HVAC control module rearward to disengage the mounting studs from the dash panel. |
35.2. | Position aside the dash insulator pad from the recirculation opening of the HVAC control module . |
35.3. | Roll the HVAC control module downward and rearward to disconnect the heater core outlet cover from the rear floor air outlet duct. |
35.4. | Remove the HVAC control module. |
Important: When installing the HVAC control module, ensure that the dash insulator pad cut-outs and the HVAC seals, studs, and drain align and seal properly to the dash panel.
2.1. | Align the heater core outlet cover to the rear floor air outlet duct. |
2.2. | Roll the HVAC control module forward and upward and align the dash insulator pad to the recirculation opening of the HVAC control module. |
2.3. | Align the mounting studs and the drain on the HVAC control module to seat against the dash panel. |
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the nuts to 10 N·m (89 lb in).
Tighten
Tighten the bolts to 25 N·m (18 lb ft).
Tighten
Tighten the bolts to 10 N·m (89 lb in).
Tighten
Tighten the bolts to 10 N·m (89 lb in).
Tighten
Tighten the bolts to 50 N·m (37 lb ft).
Tighten
Tighten the bolts to 10 N·m (89 lb in).
Tighten
Tighten the screw to 1.8 N·m (16 lb in).
Tighten
Tighten the bolts to 10 N·m (89 lb in).
Important: Reposition the heater core hose clamps in the indicated location.
Tighten
Tighten the screws to 16 N·m (12 lb ft).