Step | Action | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|
1 | Were you sent here from the A/C System Performance Test? | Go to Step 2 | |||||||
2 | Refer to the air outlet temperatures recorded during the A/C system performance test. Is there a 2 - 3 degrees difference or more in the discharge air temperature between the right and left center I/P outlets? | Go to Step 7 | Go to Step 3 | ||||||
3 | Did the customer concern mention that the A/C system outputtemperatures are good at first, but then turn warm during extended drives? | Go to Step 4 | Go to Step 5 | ||||||
4 | Increase engine speed to 2000 RPM. During extended operation of the A/C system, does the low side pressure decrease, possibly accompanied by heavy frost on the liquid line between the expansion device and the evaporator? | Go to Step 5 | |||||||
5 | Refer to the pressures recorded during the A/C system performance test. Inspect for the following conditions: Caution: Refer to Moving Parts and Hot Surfaces Caution in the Preface section.
Do the listed conditions exist? | Go to Step 7 | Go to Step 6 | ||||||
6 | Refer to the pressures recorded during the A/C system performance test. Inspect for the following conditions: Caution: Refer to Moving Parts and Hot Surfaces Caution in the Preface section.
Do the listed conditions exist? | Go to Step 8 | Go to Too Hot in Vehicle in HVAC Systems - Manual | ||||||
7 | The A/C system may be undercharged.
Is the repair complete? | Go to Step 14 | -- | ||||||
8 | The A/C system may be contaminated. View the J 43600 information screen for detection of foreign gases in the A/C system. Do foreign gases exist? | Go to Step 9 | Go to Step 10 | ||||||
9 |
Is the repair complete? | Go to Step 14 | -- | ||||||
10 | The A/C system may contain too much moisture or air.
Are the outlet temperatures within the specified ranges of the A/C Performance Test Table? | Go to Step 15 | Go to Step 11 | ||||||
11 | The A/C system may contain too much refrigerant oil.
Was there more than 148 ml ( 5 oz.) of refrigerant oil drained from the accumulator? | Go to Step 12 | Go to Step 13 | ||||||
12 |
Are the repairs complete? | Go to Step 14 | -- | ||||||
13 |
Are the repairs complete? | Go to Step 14 | -- | ||||||
14 |
Are the high and low side pressures and outlet temperatures within specifications? | Go to Step 15 | |||||||
15 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Symptoms - HVAC Systems - Manual in HVAC Systems-Manual |