Subject: | Instrument Panel Cluster (IPC) Gauges Inoperative (Reprogram
IPC) |
Models: | 2003 Cadillac Escalade, Escalade ESV, Escalade EXT |
| 2003
Chevrolet Avalanche, Silverado, Suburban, Tahoe |
| 2003 GMC Sierra, Yukon, Yukon XL |
Condition
Some customers may comment that upon vehicle start-up, all instrument panel
cluster gauges are inoperative.
Cause
During a cold start or low battery condition, a low voltage condition may cause
gauges to freeze during crank cycle.
Correction
Important: DO NOT REPLACE the following clusters unless
a reprogram does not correct this condition.
A new service calibration has been released to correct this condition. Reprogram
the IPC using the new service calibration, which was available from Techline starting
November 3, 2003 on the TIS2000 version 11.5 or later. This calibration is an electronic
calibration and is not available from GMSPO.
Warranty Information
For vehicles repaired under warranty, use:
Labor Operation
| Description
| Labor Time
|
N4199
| Instrument Panel Cluster (IPC) Module - Reprogram
| 0.4 hr
|