Removal Procedure
- Roll back the Instrument panel in the vehicle. Refer to
Instrument Panel Assembly Replacement
in Instrument Panel Gages,
and Console.
- Disconnect the electrical
connector from the recirculation actuator (19).
- Remove the screws from the recirculation actuator (19).
- Remove the recirculation actuator (19) from the HVAC module.
Installation Procedure
- Install the recirculation
actuator (19) to the HVAC module.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the screws to the recirculation actuator (19).
Tighten
Tighten the screws to 2 N·m (18 lb in).
- Connect the electrical connector to the recirculation actuator (19).
- Roll the Instrument panel forward in the vehicle. Refer to
Instrument Panel Assembly Replacement
in Instrument Panel Gages,
and Console.