The numbers below refer to the step numbers on the diagnostic table.
This checks for proper cooling system operation.
The voltage will vary between 0-12 volts during normal operation. The HVAC control assembly connector must be connected during this step.
Step | Action | Values | Yes | No | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference : HVAC Schematics DEFINITION: The temperature cannot be adjusted, or the heating is insufficient. | ||||||||||||||||||
1 | Did you review the HVAC operation and perform the necessary inspections? | -- | Go to Step 2 | |||||||||||||||
2 |
Does the blower motor operate in any of the speed positions? | -- | Go to Step 3 | Go to Blower Motor Inoperative | ||||||||||||||
3 | Does the blower motor operate at the desired speeds? | -- | Go to Step 4 | Go to Blower Motor Malfunction | ||||||||||||||
4 |
Does air flow from the correct air outlets for each mode position? | -- | Go to Step 5 | Go to Air Delivery Improper | ||||||||||||||
Inspect the cooling system for the following conditions:
Refer to Heating Performance Diagnostic in Heating, Ventilation and Air Conditioning. Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 6 | |||||||||||||||
6 |
Does the A/C compressor operate? | -- | Go to Step 7 | |||||||||||||||
7 |
Does the drive shaft on the air temperature actuator ever rotate? | -- | Go to Step 8 | Go to Step 9 | ||||||||||||||
8 | Inspect the air temperature door and the air temperature actuator for the following conditions:
Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 9 | ||||||||||||||
9 | Test the ignition 3 voltage circuit of the air temperature actuator for an open or for a high resistance. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 10 | ||||||||||||||
10 | Test the ground circuit of the air temperature actuator for an open. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 11 | ||||||||||||||
11 | Test the door control circuit of the air temperature actuator. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 12 | ||||||||||||||
Important: Ensure that the HVAC control assembly connector is connected during this step in order to avoid misdiagnosis.
Is the voltage measurement within the specified values with a smooth transition between cold and hot? | 0-12 V | Go to Step 15 | Go to Step 13 | |||||||||||||||
13 | Inspect for poor connections at the harness connector of the air temperature actuator. Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 14 | ||||||||||||||
14 | Inspect the air temperature actuator, the door, and the attaching linkage for binding or for a condition that prevents drive shaft rotation. Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 16 | ||||||||||||||
15 | Inspect for poor connections at the harness connector of the HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 17 | ||||||||||||||
16 | Replace the air temperature actuator. Refer to Air Temperature Actuator Replacement . Did you complete the replacement? | -- | Go to Step 18 | -- | ||||||||||||||
17 | Replace the HVAC control assembly. Refer to Heater and Air Conditioning Control Replacement . Did you complete the replacement? | -- | Go to Step 18 | -- | ||||||||||||||
18 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |