Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Does the folding top operate? | -- | ||
2 | Replace the folding top switch. Refer to Convertible Top Switch Replacement . Is the repair complete? | -- | System OK | -- |
3 |
Does the test lamp light? | -- | ||
4 | Replace the folding top relay. Refer to Folding Top Relay. Is the repair complete? | -- | System OK | -- |
5 | Use the J 39200 in order to measure the resistance in CKT 124 between the folding top switch connector terminal C and the folding top relay connector terminal A. Does the resistance measure within the specified range? | 0-2 ohms | ||
6 | Repair the open circuit condition in CKT 124 between the folding top switch connector terminal C and the folding top relay connector terminal A. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | System OK | -- |
7 | Use the J 39200 in order to measure the resistance in CKT 124 between the folding top switch connector terminal C and ground. Does the resistance measured equal the specified value? | Infinite | System OK | |
8 | Repair the short to ground condition in CKT 124 between the folding top switch connector terminal C and the folding top relay connector terminal A. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | System OK | -- |