Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Inspect the 20A CIG fuse for an open. Is fuse open? | -- | Go to Step 2 | Go to Step 3 |
2 | Test terminal A at cigar lighter connector for continuity to ground. Is ground present? | -- | Go to Step 4 | -- |
3 |
Is battery voltage present? | B+ | Go to Step 5 | Go to Step 7 |
4 | Repair short to ground in cigar lighter power feed circuit. Is repair complete? | -- | System OK | -- |
5 | Test terminal C for continuity to ground. Is ground present? | -- | Go to Step 6 | Go to Step 8 |
6 | Replace auxiliary outlet. Is repair complete? | -- | System OK | -- |
7 | Repair open in cigar lighter power feed circuit. Is repair complete? | -- | System OK | -- |
8 | Repair open in cigar lighter ground circuit. Is repair complete? | -- | System OK | -- |