Step | Action | Yes | No |
---|---|---|---|
1 | Was A Diagnostic System Check performed? | Go to Step 2 | |
2 |
Does the test lamp light? | Go to Step 3 | Go to Step 4 |
3 | Connect the test lamp between terminal A and terminal B of the inoperative back-up lamp harness connector. Does the test lamp light? | Go to Step 5 | Go to Step 6 |
4 | Repair the open in Back up Lamp feed Circuit between splice S400 and the inoperative back-up lamp. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | System OK | -- |
5 | Replace the inoperative back-up lamp or connector. Is the repair complete? | System OK | -- |
6 | Repair the open in the Ground Circuit between the inoperative back-up lamp and ground G150. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | System OK | -- |