Removal Procedure
- Remove the IP compartment. Refer to
Instrument Panel Compartment Door Replacement
in Instrument Panel,
Gauges and Console.
- Disconnect the temperature cable from the temperature actuator.
- Remove the screws from
the temperature actuator.
- Remove the temperature actuator from the HVAC module assembly.
Installation Procedure
- Install the temperature
actuator to the HVAC module assembly.
- Install the temperature actuator screws.
Tighten
Tighten the air temperature actuator to 2 N·m18 lb. in.
- Connect the temperature cable to the temperature actuator.
- Install the IP compartment. Refer to
Instrument Panel Compartment Door Replacement
in Instrument
Panel, Gauges and Console.