Step | Action | Value(s) | Yes | No | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
The following test measures the air conditioning (A/C) system operating efficiency by comparing the following:
| ||||||||||||||||||||||||||
1 |
The low and high side pressure readings should be almost equal to each other once the system has come to rest. Are both the low and high side pressures above the specified value ? | 345 kPa (50 psi) | Go to Leak Testing | |||||||||||||||||||||||
2 |
Does the A/C compressor clutch engage? | -- | Go to HVAC Compressor Clutch Does Not Disengage in HVAC Systems - Manual | |||||||||||||||||||||||
3 |
Important: Record the relative humidity and the ambient temperature AT THE TIME OF THE TEST.
This will take approximately 3 minutes.
Does all the data recorded fall within the specified ranges of the table below? | -- | ||||||||||||||||||||||||
4 | Compare the recorded pressures to the A/C System Pressure - Zone Classification Graph. Do both the low and high side pressures fall within Zone A on the graph? | -- | Go to Cooling Insufficient - Air Conditioning (A/C) System - Pressure Zone A | |||||||||||||||||||||||
5 | Do the pressures fall within Zone B? | -- | Go to Cooling Insufficient - Air Conditioning (A/C) System - Pressure Zone B | |||||||||||||||||||||||
6 | Do the pressures fall within Zone C? | -- | Go to Cooling Insufficient - Air Conditioning (A/C) System - Pressure Zone C | |||||||||||||||||||||||
7 | Do the pressures fall within Zone D? | -- | Go to Cooling Insufficient - Air Conditioning (A/C) System - Pressure Zone D | |||||||||||||||||||||||
8 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Symptoms in HVAC System - Manual |
Temperature | Humidity | Low Gauge Pressure | High Gauge Pressure | Center Outlet Temperature |
---|---|---|---|---|
21°-27°C (70°-80°F) | Less than 50% | 165-234 kPa (24-34 psi) | 793-1310 kPa (115-190 psi) | 3°-9°C (38°-48°F) |
More than 50% | 172-255 kPa (25-37 psi) | 793-1379 kPa (115-200 psi) | 4°-13°C (40°-55°F) | |
27°-33°C (80°-90°F) | Less than 50% | 193-262 kPa (28-38 psi) | 965-1482 kPa (140-215 psi) | 3°-13°C (38°-55°F) |
More than 50% | 207-276 kPa (30-40 psi) | 1034-1620 kPa (150-235 psi) | 7°-18°C (45°-65°F) | |
33°-38°C (90°-100°F) | Less than 40% | 234-296 kPa (34-43 psi) | 1138-1793 kPa (165-260 psi) | 7°-17°C (45°-63°F) |
More than 40% | 251-331 kPa (36-48 psi) | 1276-1862 kPa (185-270 psi) | 13°-20°C (55°-68°F) | |
38°-44°C (100°-110°F | Less than 20% | 276-338 kPa (40-49 psi) | 1448-2000 kPa (210-290 psi) | 12°-18°C (53°-64°F) |
More than 20% | 296-359 kPa (43-52 psi) | 1517-2137 kPa (220-310 psi) | 14°-21°C (58°-70°F) |