Removal Procedure
- Recover the refrigerant.
Refer to Refrigerant Recovery and Recharging
.
- Disconnect the air conditioning (A/C) compressor and condenser
hose bolt at the accumulator.
- Remove the accumulator bolt (2) at the module.
- Remove the accumulator hose bracket nut (1) at the strut tower.
- Remove the accumulator bracket bolt.
- Remove the accumulator from the bracket.
- Discard the O-rings.
Installation Procedure
- Before installing a new,
or reinstalling the old accumulator perform the following:
1.1. | Drain, measure and record the amount of poly-alkylene
glycol (PAG) oil in the accumulator that was removed. |
1.2. | Add 60 ml (2 oz) of new, clean PAG oil MORE than
the amount drained from the removed accumulator. |
- Install the new O-ring.
- Install the accumulator to the bracket.
- Install the accumulator bracket bolt.
Tighten
Tighten the accumulator bracket bolt to 6 N·m (53 lb in).
- Install the accumulator hose bracket nut (1) at the strut tower.
Tighten
Tighten the accumulator hose bracket nut (1) at the strut tower to 8 N·m
(71 lb in).
- Install the accumulator bolt (2) at the module.
Tighten
Tighten the accumulator bolt (2) at the module to 16 N·m
(12 lb ft).
- Connect the A/C compressor and condenser hose bolt at the accumulator.
Tighten
Tighten the A/C compressor and condenser hose bolt at the accumulator
to 16 N·m (12 lb ft).
- Recharge the A/C system. Refer to Refrigerant Recovery and Recharging
.
- Perform a leak test on the A/C system. Refer to
Leak Testing
.