Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the Horns System Check Performed? | -- | Go to Step 2 | Go to Horns System Check |
2 | Remove the horn relay from the underhood fuse block. Does the horn continue to sound? | -- | Go to Step 3 | Go to Step 4 |
3 | Repair the short to voltage in CKT 1329 (DK GRN) between the underhood fuse block connector C4 cavity A6 and horn cavity B, LH/RH. Is the repair complete? | -- | Go to Horns System Check | -- |
4 | Connect a test lamp from horn relay cavity 1 to B+. Does the test lamp light? | -- | Go to Step 5 | Go to Step 6 |
5 |
Does the test lamp light? | -- | Go to Step 7 | Go to Step 8 |
6 | Replace the horn relay. Refer to Horn Relay Replacement. Is the repair complete? | -- | Go to Horns System Check | -- |
7 | Locate and repair the short to ground in CKT 28 (BLK) between the horn relay and the horn switch/BCM. Is the repair complete? | -- | Go to Horns System Check | -- |
8 | Replace the horn switch. Refer to Horn Replacement. Is the repair complete? | -- | Go to Horns System Check | -- |