Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Important: Check for inoperative lamp/bulb before beginning diagnostic procedure. | ||||
1 | Did you perform the Lighting Diagnostic System Check? | -- | Go to Step 2 | |
2 | Connect a test lamp from CKT 1732 (ORN) to the inoperative reading lamp to ground. Does the test lamp light? | -- | Go to Step 3 | Go to Step 5 |
3 | Inspect for an open in CKT 1350 (BLK) to ground G400. Did you find an open? | -- | Go to Step 4 | Go to Step 6 |
4 | Repair the open in CKT 1350 (BLK) to ground G400. Is the repair complete? | -- | Go to Step 7 | -- |
5 | Repair the open in CKT 1732 (ORN) from the reading lamp to splice S301. Is the repair complete? | -- | Go to Step 7 | -- |
6 | Replace the reading lamp bulb Dome and Reading Lamp Bulb Replacement . Is the repair complete? | -- | Go to Step 7 | -- |
7 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |