Removal Procedure
Caution: When you are carrying an undeployed inflator module:
• | Do not carry the inflator module by the wires or connector on
the inflator module |
• | Make sure the bag opening points away from you |
When you are storing an undeployed inflator module, make sure the bag
opening points away from the surface on which the inflator module rests.
When you are storing a steering column, do not rest the column with the bag
opening facing down and the column vertical. Provide free space for the
air bag to expand in case of an accidental deployment. Otherwise, personal
injury may result.
- Disable the SIR system. Refer to
Disabling the SIR System
.
- Remove the instrument panel (I/P) compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel,
Gages, and Console.
- Remove the connector position assurance (CPA) from the inflatable
restraint I/P module yellow 2-way connector (2).
- Disconnect the inflatable restraint I/P module yellow 2-way connector (2).
- Remove the inflatable restraint I/P module screws (3).
- Remove the inflatable restraint I/P module (1).
Installation Procedure
- Install the inflatable
restraint instrument panel (I/P) module (1).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the screws (3) that secure the inflatable restraint I/P
module.
Tighten
Tighten the screws to 10 N·m (89 lb in).
- Connect the inflatable restraint I/P module yellow 2-way connector (2).
- Install the CPA to the inflatable restraint I/P module
yellow 2-way connector (2).
- Install the I/P compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel, Gages, and Console.
- Enable the SIR system. Refer to
Enabling the SIR System
.