Removal Procedure
- Remove the wiper motor module. Refer to
Windshield Wiper System Module Replacement.
- Remove the fasteners (2) from the wiper motor covers (3).
- Carefully remove the wiper motor cover from the wiper motor housing (1).
Installation Procedure
- Ensure the wiper motor cover housing sealing surface is clean and dry.
- Position the wiper motor cover (3) to the wiper motor housing.
Notice: Refer to Fastener Notice in the Preface section.
Important: To ensure proper wiper cover seal to wiper motor housing contact, the cover fasteners need to be equally tightened to the motor housing.
- Install the wiper motor cover fasteners (2).
- Tighten the fasteners in an X pattern as follows:
Tighten
• | Tighten the fasteners on the first pass to 0.67 N·m(6 lb in). |
• | Tighten the fasteners on the second pass to 1.35 N·m(12 lb in). |
• | Tighten the fasteners on the third and final pass to 2.0 N·m(18 lb in) to ensure equal sealing pressure is applied to the cover seal. |
- Install the wiper motor module. Refer to
Windshield Wiper System Module Replacement.