• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Recirculation 5-Volt Reference | B0248 61, B0408 61, B0418 61, B0268 61, B3531 61, B0428 61 | B3773 06 | B0268 61, B3773 06 | -- |
Recirculation Door Position Signal | B0268 61 | B3773 06 | B0268 61, B3773 06 | -- |
Recirculation Door Control A | B0268 61 | B0268 61 | B0268 61 | -- |
Recirculation Door Control B | B0268 61 | B0268 61 | B0268 61 | -- |
Recirculation Low Reference | -- | B0268 61 | -- | -- |
Driver Air Temperature 5-Volt Reference | B0248 61, B0408 61, B0418 61, B0268 61, B3531 61, B0428 61 | B0413 06 | B0408 61, B0413 06 | -- |
Driver Air Temperature Door Position Signal | B0408 61 | B0413 06 | B0408 61, B0413 06 | -- |
Driver Air Temperature Door Control A | B0408 61 | B0408 61 | B0408 61 | -- |
Driver Air Temperature Door Control B | B0408 61 | B0408 61 | B0408 61 | -- |
Driver Air Temperature Low Reference | -- | B0408 61 | -- | -- |
Passenger Air Temperature 5-Volt Reference | B0248 61, B0408 61, B0418 61, B0268 61, B3531 61, B0428 61 | B0418 61 | B0268 61, B0423 06 | -- |
Passenger Air Temperature Door Position Signal | B0418 61 | B0268 61, B0423 06 | B0418 61 | -- |
Passenger Air Temperature Door Control A | B0418 61 | B0418 61 | B0418 61 | -- |
Passenger Air Temperature Door Control B Circuit | B0418 61 | B0418 61 | B0418 61 | -- |
Passenger Air Temperature Low Reference | -- | B0418 61 | -- | -- |
Mode 5-Volt Reference | B0248 61, B0408 61, B0418 61, B0268 61, B3531 61, B0428 61 | B0248 61 | B0248 61, B3761 06 | -- |
Mode Door Position Signal | B0248 61 | B0248 61, B3761 06 | B0248 61, B3761 06 | -- |
Mode Door Control A | B0248 61 | B0248 61 | B0248 61 | -- |
Mode Door Control B | B0248 61 | B0248 61 | B0248 61 | -- |
Mode Low Reference | -- | B0248 61 | -- | -- |
Auxiliary Air Temperature 5-Volt Reference | B0248 61, B0408 61, B0418 61, B0268 61, B3531 61, B0428 61 | B0428 61 | B0428 61, B0433 06 | -- |
Auxiliary Air Temperature Door Position Signal | B0428 61 | B0428 61, B0433 06 | B0428 61, B0433 06 | -- |
Auxiliary Air Temperature Door Control A | B0428 61 | B0428 61 | B0428 61 | -- |
Auxiliary Air Temperature Door Control B | B0428 61 | B0428 61 | B0428 61 | -- |
Auxiliary Air Temperature Low Reference | -- | B0428 61 | -- | -- |
Auxiliary Mode 5-Volt Reference | B0248 61, B0408 61, B0418 61, B0268 61, B3531 61, B0428 61 | B3531 61 | B3531 61, B3782 61 | -- |
Auxiliary Mode Door Position Signal | B3531 61 | B3531 61, B3782 61 | B3531 61, B3782 61 | -- |
Auxiliary Mode Door Control A | B3531 61 | B3531 61 | B3531 61 | -- |
Auxiliary Mode Door Control B | B3531 61 | B3531 61 | B3531 61 | -- |
Auxiliary Mode Low Reference | -- | B3531 61 | -- | -- |
The HVAC control module controls the HVAC door actuators to regulate the airflow through the HVAC system. Each actuator consists of an electric motor and a potentiometer. The module supplies a low reference and 5-volt reference source voltage to the potentiometer. The HVAC control module monitors the voltage drop across the potentiometer on the door position signal circuit. When the actuator shaft rotates, the voltage on the door position signal circuit changes. The HVAC control module supplies the actuator motor with a 12-volt control circuit and a ground control circuit. The HVAC module controls the direction of the actuator door by changing the polarity of the control circuits.
• | Ignition ON. |
• | Ignition voltage is between 9-16 volts. |
• | The HVAC module is ON. |
The actual door position differs from the commanded door position by greater than 4 counts or the HVAC control module detects the door position signal circuit is less than 7 counts or greater than 250 counts.
Driver A and driver B circuits are deactivated for the appropriate actuator.
• | The DTC becomes history when the HVAC control module no longer detects the condition that set the DTC. |
• | The history DTC will clear after 100 fault free ignition cycles. |
• | The DTC can be cleared with a scan tool. |
Air Temperature Description and Operation
Control Module References for scan tool information
⇒ | If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the HVAC control module. |
⇒ | If less than the specified range, test the 5-volt reference circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the HVAC control module. |
⇒ | If greater than the specified range, test the 5-volt reference circuit for a short to voltage. If the circuit tests normal, replace the HVAC control module. |
⇒ | If greater than the specified range, test the signal circuit for a short to ground. If the circuit tests normal, replace the HVAC control module. |
⇒ | If less than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the HVAC control module. |
Important: Apply power and ground to the actuator for no more than 2 seconds at a time or the actuator could be damaged.
Important: When performing the following tests, make sure that the device is not already at its end of travel position by switching the polarity applied to the actuator twice if the actuator did not move in one direction.
⇒ | If the actuator does not move in both directions, test the control circuits for a short to voltage, short to ground or an open/high resistance. If the circuits test normal, test or replace the inoperative actuator. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.