• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
B+, BCM X4 terminal 2 | B2615 00 | B2615 00 | -- | -- |
Courtesy Lamps Supply Voltage | B2615 00 | 2 | 1 | -- |
Right Front Turn Signal Lamp Supply Voltage | B2615 00 | 3 | 4 | -- |
1. Courtesy Lamps Always On 2. Courtesy Lamps Inoperative 3. Right Front Turn Signal Inoperative 4. Right Front Turn Signal Always ON |
Battery voltage for the courtesy lamps is supplied at all times, from the CTSY/RF TRN Fuse located in the rear fuse block, to the body control module (BCM). When the BCM receives a signal to command the courtesy lamps ON, it then applies voltage through the courtesy lamps supply voltage circuits to the courtesy lamps listed below.
• | Courtesy Lamp Module |
• | Left and right roof rail courtesy/reading lamps |
• | Left and right rear door courtesy/puddle lamps |
• | Overhead console lamp |
• | The BCM attempts to illuminate the courtesy lamps. |
• | Engine ON, the BCM attempts to illuminate the day time running lamps. |
• | Ignition ON with the right turn signal switch active, the BCM attempts to illuminate the right front turn signal. |
• | The BCM detects a short to ground on the courtesy lamp supply voltage circuit. |
• | The BCM detects a short to ground on the right front turn signal supply voltage circuit. |
The BCM will not attempt to activate courtesy lamps or the right front turn signal.
• | The condition responsible for setting the DTC no longer exists. |
• | A history DTC will clear once 100 consecutive malfunction ignition cycles have occurred. |
Interior Lighting Systems Description and Operation
Control Module References for Scan Tool Information
Ignition ON, command the Courtesy Lamps ON and OFF with a scan tool. The courtesy lamps should turn ON and OFF when changing between commanded states.
⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and the B+ circuit fuse is open, test the supply voltage circuits listed below for a short to ground. |
• | Right front turn signal lamp supply voltage terminal 5 X4 |
• | Courtesy lamp supply voltage terminal 1 X6 |
• | Courtesy lamp supply voltage terminal 5 X2 |
• | Right front turn signal lamp supply voltage terminal 5 X4 |
• | Courtesy lamp supply voltage terminal 1 X6 |
• | Courtesy lamp supply voltage terminal 5 X2 |
⇒ | If the DTC resets, test the supply voltage circuits for a short to ground. If the circuits test normal, replace the BCM. |
⇒ | If the DTC resets, test or replace the component responsible for setting the DTC. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for BCM replacement, setup, and programming |