GM Service Manual Online
For 1990-2009 cars only

Diagnostic Instructions

    • Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
    • Review Strategy Based Diagnosis for an overview of the diagnostic approach.
    •  Diagnostic Procedure Instructions provides an overview of each diagnostic category.

Diagnostic Fault Information

Circuit

Short to Ground

Open/High Resistance

Short to Voltage

Signal Performance

Air Suspension Exhaust Valve Solenoid Control

C0660 00

C0660 00

C0660 00

C0660 58

Air Suspension Exhaust Valve Solenoid B+

C0660 00, C0712 00, C0716 00, C0717 00

C0660 00

C0660 00

C0660 58

Leveling Compressor Relay Coil B+

C0660 00, C0712 00, C0716 00, C0717 00

--

--

--

Leveling Compressor Valves B+

C0660 00, C0712 00, C0716 00, C0717 00

--

--

--

Leveling Compressor Relay Coil Control

C0712 00

C0712 00

C0712 00

--

RH Compressor Control Valve Control

C0717 00

C0717 00

C0717 00

--

LH Compressor Control Valve Control

C0716 00

C0716 00

C0716 00

--

Left Rear Suspension Position Sensor Low Reference

--

--

C0660 00, C0712 00, C0716 00, C0717 00

--

Right Rear Suspension Position Sensor Low Reference

--

--

C0660 00, C0712 00, C0716 00, C0717 00

--

Leveling Compressor Control

2

2

1

--

Level Control Compressor Ground

--

2

--

--

1. Rear of Vehicle High

2. Rear of Vehicle Low

Circuit/System Description

The air suspension system uses level sensors, a control module, compressor, pressure sensor, right and left pressure valves, and exhaust valve to increase or decrease air pressure in the system to control trim height. The air suspension control module supplies battery voltage to the exhaust valve, pressure valves, and compressor relay. The air suspension control module also controls the ground circuits that activate the exhaust valve, pressure valves, and compressor relay which maintain trim height based on the level sensor input voltage.

Diagnostic Aids

    • If the compressor runs continuously, inspect the system for any leaks or damaged components.
    • Performing the Suspension Position Calibration procedure may correct the condition.

Reference Information

Schematic Reference

Automatic Level Control Schematics

Connector End View Reference

Component Connector End Views

Description and Operation

Automatic Level Control Description and Operation

Electrical Information Reference

    •  Circuit Testing
    •  Connector Repairs
    •  Testing for Intermittent Conditions and Poor Connections
    •  Wiring Repairs

Scan Tool Reference

Control Module References for scan tool information

Circuit/System Verification

  1. Ignition ON, command the Compressor Relay ON and OFF with a scan tool. Verify that the compressor turns ON and OFF with each command.
  2. If the compressor does not operate or operates continuously, refer to Compressor Malfunction.
  3. Ignition ON, command the exhaust valve ON and OFF with a scan tool. Verify the exhaust valve clicks and the vehicle height changes with each command.
  4. If the exhaust valve does not click or the vehicle height does not change, refer to Exhaust Valve Malfunction.
  5. Ignition ON, command the LR and RR Control Valves ON and OFF with a scan tool. Verify the control valves click and the vehicle applicable rear corner height changes with each command.
  6. If a control valve does not click or the applicable rear corner height does not change, refer to Control Valve Malfunction.

Circuit/System Testing

Compressor Malfunction

  1. Ignition OFF, disconnect the harness connector at the leveling compressor.
  2. Test for less than 1 ohm between the compressor ground circuit terminal and ground.
  3. If greater than the specified range, test the ground circuit for an open/high resistance. If the circuit tests normal, test or replace the air compressor assembly.
  4. Connect the test lamp between the control circuit terminal and ground.
  5. Ignition ON, command the compressor relay ON and OFF with the scan tool. The test lamp should turn ON and OFF when changing between the commanded states.
  6. If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal and the ELC MDL fuse is open, test or replace the ALC compressor assembly. If the circuit tests normal and the ELC MDL fuse is not open, test or replace the ELC compressor relay.
    If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, test or replace the ELC compressor relay.
  7. Test or replace the air compressor.

Exhaust Valve Malfunction

  1. Ignition OFF, connect a test lamp between the exhaust valve connector control circuit terminal and the B+ circuit terminal.
  2. Ignition ON, command the exhaust valve ON and OFF with a scan tool. The test lamp should turn ON and OFF when changing between the commanded states.
  3. If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the air suspension control module.
    If the test lamp is always OFF, test the control circuit for an open/high resistance. If the circuit tests normal, replace the air suspension control module.
  4. If all circuits test normal, test or replace the air suspension compressor assembly.

Control Valve Malfunction

  1. Ignition OFF, connect a test lamp between the affected control valve connector control circuit terminal and the B+ circuit terminal.
  2. Ignition ON, command the affected control valve ON and OFF with a scan tool. The test lamp should turn ON and OFF when changing between the commanded states.
  3. If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the air suspension control module.
    If the test lamp is always OFF, test the control circuit for an open/high resistance. If the circuit tests normal, replace the air suspension control module.
  4. If all circuits test normal, test or replace the air suspension compressor assembly.

Component Testing

  1. Ignition OFF, disconnect the relay.
  2. Test for 50-200 ohms between terminals 85 and 86.
  3. If not the specified value, replace the relay.
  4. Test for infinite resistance between the following terminals:
  5. • 30 and 86
    • 30 and 87
    • 30 and 85
    • 85 and 87
    If the resistance is not within the specified range, replace the relay.
  6. Install a 20A fused jumper wire between relay terminal 85 and 12 volts. Install a jumper wire between relay terminal 86 and ground. Test for less than 2.0 ohms between terminals 30 and 87.
  7. If greater than the specified range, replace the relay.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

    •  Suspension Position Calibration
    •  Automatic Level Control Air Compressor Replacement
    •  Compressor Assembly Automatic Level Control Air Replacement
    •  Air Spring Replacement
    •  Air Suspension Air Line Replacement
    •  Relay Replacement
    •  Control Module References for air suspension control module replacement, setup and programming