Radiator Surge Tank Outlet Hose/Pipe Replacement LLT
Callout
| Component Name
|
Preliminary Procedure
- Partially drain the cooling system. Refer to
Cooling System Draining and Filling.
- Remove the fuel pipe shield. Refer to
Fuel Pipe Shield Replacement.
|
1
| Outlet Pipe Bolt (Attached to Head)
Notice: Refer to Fastener Notice in the Preface section.
Tighten 23 N·m (17 lb ft) |
2
| Outlet Pipe Bolt (Attached to Thermostat Housing)
Tighten 10 N·m (89 lb in) |
3
| Radiator Surge Tank Outlet Pipe
|
4
| O-ring
ProcedureApply a small amount of lubricant to the surge tank pipe O-ring to allow the O-ring to seal properly.
|
5
| Spring Clamp
|
Radiator Surge Tank Outlet Hose/Pipe Replacement LY7/LLT
Special Tools
J 38185
Hose Clamp Pliers
Removal Procedure
- Drain the cooling system. Refer to
Cooling System Draining and Filling
.
- Position
J 38185
to the clamp in order to remove the outlet hose (2) from
the surge tank (1).
- Loosen the bolt on the bracket which secures the surge tank outlet hose to the engine.
- Remove the windshield wiper transmission. Refer to
Windshield Wiper Transmission Replacement
.
- Position
J 38185
to the clamp in order to remove the surge tank outlet hose from the thermostat assembly.
- Remove the surge tank outlet hose/pipe from the engine.
Installation Procedure
- Position the surge tank outlet hose/pipe to the engine.
- Position
J 38185
to the clamp in order to connect the surge tank outlet hose to the thermostat assembly.
- Install the windshield wiper transmission. Refer to
Windshield Wiper Transmission Replacement
.
Notice: Refer to Fastener Notice in the Preface section.
- Install the bolt to the bracket securing the surge tank outlet pipe to the engine.
Tighten
Tighten the bolt to 9 N·m (80 lb in).
- Position
J 38185
to the clamp in order to connect the outlet hose (2)
to the surge tank (1).
- Fill the cooling system. Refer to
Cooling System Draining and Filling
.