Tools Required
J 39400-A
Halogen Leak Detector
Removal Procedure
Important: No schrader valve appears under the pressure sensor.
- Recover the refrigerant. Refer to
Refrigerant Recovery and Recharging
.
- Remove the air cleaner assembly. Refer to the following:
- Disconnect the electrical connector (1) from the A/C refrigerant pressure sensor (2).
- Remove the A/C refrigerant pressure sensor.
Installation Procedure
- Lubricate the O-ring with refrigerant oil. Refer to
O-Ring Replacement
.
Notice: Refer to Fastener Notice in the Preface section.
- Install the A/C refrigerant pressure sensor (2).
Tighten
Tighten the sensor to 9.8 N·m (87 lb in).
- Connect the electrical connector (1) to the A/C refrigerant pressure sensor.
- Install the air cleaner assembly. Refer to the following:
- Evacuate and recharge the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Leak test the fittings of the component using
J 39400-A
.