Table 1: | A/C Performance Table (LY7, LP1) |
This test measures the operating efficiency of the A/C system under the following conditions:
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||||||||||
Are both the low side and high side pressures above the specified value? | More than 16°C (60°F) - 345 kPa (50 psi) More than 24°C (75°F) - 483 kPa (70 psi) More than 33°C (90°F) - 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||||||||||
Important:
Important: Make sure that the compressor is engaged when taking the data. Press the RESET button, before using the print function of the J 43600 .
Does all the data recorded fall within the specified ranges of the A/C Performance Table? | -- | Go to Step 8 | Go to Step 3 | |||||||||||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges of the A/C Performance Table:
Does all the data recorded fall within the specified ranges? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||||||||||
4 | See the A/C system Pressure -- Zone Classification chart. Do the high and low side pressures fall within the specified ranges, but the outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||||||||||
7 | Is the high side pressure greater than or within the specified range, but the low side pressure is less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK |
Ambient Air Temperature | Relative Humidity | Service Port Pressure | Maximum Left Center Discharge Air Temperature | |
---|---|---|---|---|
Low Side | High Side | |||
13-18°C (55-65°F) | 0-100% | 150-208 kPa (21-30 psi) | 630-1040 kPa (91-151 psi) | 10°C (50°F) |
19-24°C (66-75°F) | Below 40% | 150-206 kPa (21-30 psi) | 700-1110 kPa (101-161 psi) | 10°C (50°F) |
Above 40% | 153-222 kPa (22-32 psi) | 810-1230 kPa (117-179 psi) | 11°C (52°F) | |
25-29°C (76-85°F) | Below 35% | 155-215 kPa (22-31 psi) | 960-1280 kPa (139-186 psi) | 9°C (50°F) |
35% to 50% | 164-219 kPa (23-32 psi) | 1020-1320 kPa (148-192 psi) | 10°C (50°F) | |
Above 50% | 170-226 kPa (24-33 psi) | 1060-1390 kPa (153-202 psi) | 12°C (54°F) | |
30-35°C (86-95°F) | Below 30% | 170-229 kPa (24-33 psi) | 1150-1490 kPa (166-216 psi) | 11°C (52°F) |
30% to 50% | 174-229 kPa (25-33 psi) | 1190-1530 kPa (172-222 psi) | 12°C (54°F) | |
Above 50% | 179-230 kPa (26-33 psi) | 1240-1580 kPa (180-229 psi) | 12°C (54°F) | |
36-41°C (96-105°F) | Below 20% | 188-245 kPa (27-36 psi) | 1380-1710 kPa (200-249 psi) | 13°C (55°F) |
20% to 40% | 188-241 kPa (27-35 psi) | 1400-1730 kPa (230-251 psi) | 13°C (55°F) | |
Above 40% | 186-238 kPa (27-35 psi) | 1430-1750 kPa (207-254 psi) | 15°C (56°F) | |
42-46°C (106-115°F) | Below 20% | 207-259 kPa (30-38 psi) | 1620-1900 kPa (235-276 psi) | 15°C (56°F) |
Above 20% | 205-252 kPa (29-37 psi) | 1630-1910 kPa (236-277 psi) | 15°C (56°F) | |
47-49°C (116-120°F) | Below 30% | 219-263 kPa (31-38 psi) | 1820-2020 kPa (264-293 psi) | 16°C (61°F) |
Table 1: | A/C Performance Table (LS2) |
This test measures the operating efficiency of the A/C system under the following conditions:
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||
Are both the low side and high side pressures above the specified value? | More than 16°C (60°F) - 345 kPa (50 psi) More than 24°C (75°F) - 483 kPa (70 psi) More than 33°C (90°F) - 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Make sure that the compressor is engaged when taking the data. Press the RESET button, before using the print function of the J 43600 .
Does all the data recorded fall within the specified ranges of the A/C Performance Table? | -- | Go to Step 8 | Go to Step 3 | |||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges of the A/C Performance Table:
Does all the data recorded fall within the specified ranges? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||
4 | See the A/C system Pressure - Zone Classification chart. Do the high and low side pressures fall within the specified ranges, but the outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||
7 | Is the high side pressure greater than or within the specified range, but the low side pressure is less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK |
Ambient Air Temperature | Relative Humidity | Service Port Pressure | Maximum Left Center Discharge Air Temperature | |
---|---|---|---|---|
Low Side | High Side | |||
13-18°C (55-65°F) | 0-100% | 150-212 kPa (22-31 psi) | 990-1730 kPa (144-251 psi) | 8°C (46°F) |
19-24°C (66-75°F) | Below 40% | 150-214 kPa (22-31 psi) | 890-1560 kPa (129-226 psi) | 8°C (46°F) |
Above 40% | 152-234 kPa (22-34 psi) | 1210-1840 kPa (176-267 psi) | 10°C (50°F) | |
25-29°C (76-85°F) | Below 35% | 162-231 kPa (24-34 psi) | 1310-1760 kPa (190-255 psi) | 10°C (50°F) |
35-50% | 172-235 kPa (25-34 psi) | 1440-1820 kPa (209-264 psi) | 10°C (50°F) | |
Above 50% | 179-244 kPa (28-40 psi) | 1550-1930 kPa (225-280 psi) | 11°C (52°F) | |
30-35°C (86-95°F) | Below 30% | 186-254 kPa (27-37 psi) | 1610-2050 kPa (234-298 psi) | 12°C (54°F) |
30-50% | 190-255 kPa (28-37 psi) | 1670-2050 kPa (242-298 psi) | 12°C (54°F) | |
Above 50% | 195-256 kPa (28-37 psi) | 1740-2040 kPa (253-296 psi) | 13°C (55°F) | |
36-41°C (96-105°F) | Below 20% | 214-281 kPa (31-41 psi) | 1980-2400 kPa (287-348 psi) | 14°C (57°F) |
20-40% | 214-277 kPa (31-40 psi) | 1980-2320 kPa (287-337 psi) | 14°C (57°F) | |
Above 40% | 215-272 kPa (31-39 psi) | 1970-2230 kPa (286-324 psi) | 15°C (59°F) | |
42-46°C (106-115°F) | Below 20% | 243-303 kPa (35-44 psi) | 2360-2690 kPa (343-390 psi) | 17°C (63°F) |
Above 20% | 241-295 kPa (35-43 psi) | 2320-2540 kPa (337-369 psi) | 16°C (61°F) | |
47-49°C (116-120°F) | Below 30% | 263-311 kPa (38-45 psi) | 2610-2770 kPa (379-402 psi) | 18°C (64°F) |