Diagnostic Instructions
DTC Descriptors
DTC P0133: HO2S Slow Response Sensor 1
DTC P0134: HO2S Circuit Insufficient Activity Sensor 1
DTC P0140: HO2S Circuit Insufficient Activity Sensor 2
DTC P1133: HO2S Insufficient Switching Sensor 1
DTC P1134: HO2S Transition Time Ratio Sensor 1
DTC P2A00: HO2S Circuit Closed Loop (CL) Performance Sensor 1
DTC P2A01: HO2S Circuit Closed Loop (CL) Performance Sensor 2
Diagnostic Fault Information
HO2S Sensor 1
Circuit
| Short to Ground
| High Resistance
| Open
| Short to Voltage
| Signal Performance
|
HO2S High Signal
| P0131, P0132, P1133, P1134, P2A00
| P0131, P0132, P0133, P0134, P1133, P1134, P2A00
| P0131, P0132, P0133, P0134, P1133, P1134, P2A00
| P0132, P0134, P1133, P1134, P2A00
| P0133, P0134, P1133, P1134, P2A00
|
HO2S Low Signal
| P2A00
| P0131, P0132, P0133, P0134, P1133, P2A00
| P0131, P0132, P0133, P0134, P0137, P0138, P0140, P1133, P1134, P2A00
| P0134, P1133, P1134, P2A00
| P2A00
|
HO2S Sensor 2
Circuit
| Short to Ground
| High Resistance
| Open
| Short to Voltage
| Signal Performance
|
HO2S High Signal
| P0137, P0140, P2A01
| P0137, P0140, P2A01
| P0137, P0140, P2A01
| P0138, P0140, P2A01
| P0140, P2A01
|
HO2S Low Signal
| P2A01
| P0137, P0138, P0140, P2A01
| P0137, P0138, P0140, P2A01
| P0138, P0140, P2A01
| P2A01
|
Typical Scan Tool Data
HO2S Sensor 1
HO2S Sensor Voltage Circuits
| Normal Range
| Short to Ground
| Open
| Short to Voltage
|
HO2S High Signal
| 50-850 mV
| 0-45 mV
| Approximately 450 mV
| Approximately 1106 mV
|
HO2S Low Signal
| 50-850 mV
| 50-850 mV
| 400-600 mV
| 50-850 mV
|
HO2S Sensor 2
HO2S Sensor Voltage Circuits
| Normal Range
| Short to Ground
| Open
| Short to Voltage
|
HO2S High Signal
| 50-850 mV
| 0-45 mV
| Approximately 450 mV
| Approximately 1106 mV
|
HO2S Low Signal
| 50-850 mV
| 50-850 mV
| 400-600 mV
| 50-850 mV
|
Circuit/System Description
Heated oxygen sensors (HO2S) are used for fuel control and post catalyst monitoring. Each HO2S compares the oxygen content of the surrounding air with the oxygen content in the exhaust stream. The HO2S must reach operating temperature to provide an accurate
voltage signal. Heating elements inside the HO2S minimize the time required for the sensors to reach operating temperature. The control module supplies the HO2S with a reference, or bias, voltage of about 450 mV. When the engine is first started, the
control module operates in Open Loop, ignoring the HO2S voltage signal. Once the HO2S reaches operating temperature and Closed Loop is achieved, the HO2S generates a voltage within a range of 0-1,000 mV that fluctuates above and below bias voltage.
High HO2S voltage indicates a rich exhaust stream. Low HO2S voltage indicates a lean exhaust stream.
Conditions for Running the DTC
P0133
• | DTCs P0030, P0053, P0068, P0101, P0102, P0103, P0107, P0108, P0112, P0113, P0116, P0117, P0118, P0120, P0121, P0122, P0123, P0128, P0131, P0132, P0134, P0135, P0201, P0202, P0203, P0204, P0205, P0206, P0220, P0222, P0223, P0300, P0442, P0443,
P0446, P0449, P0451, P0452, P0454, P0455, P0496, P1516, P2101, P2119, P2135, P2176 are not set. |
• | The system voltage is between 10-18 volts. |
• | The scan tool special functions are not active. |
• | The HO2S Sensor 1 Heater command parameter is ON. |
• | The ECT sensor parameter is more than 65°C (149°F). |
• | The Engine Run Time parameter is more than 60 seconds. |
• | The vehicle is not in Park, Reverse, or Neutral. |
• | The Loop Status parameter is closed. |
• | The MAF sensor parameter is between 15-30 g/s. |
• | The TP Indicated Angle parameter is more than 3.5 percent. |
• | The Engine Speed parameter is between 1,300-3,000 RPM. |
• | The evaporative emission (EVAP) system is purging. |
• | The Barometric (BARO) parameter is at least 69.8 kPa. |
• | The above conditions have been met for one second. |
P0134
• | DTCs P0030, P0053, P0068, P0101, P0102, P0103, P0107, P0108, P0112, P0113, P0116, P0117, P0118, P0120, P0121, P0122, P0123, P0128, P0201, P0202, P0203, P0204, P0205, P0206, P0220, P0222, P0223, P0442, P0443, P0446, P0449, P0451, P0452, P0453,
P0454, P0455, P0496, P1516, P2101, P2119, P2135, P2176 are not set. |
• | The system voltage is between 10-18 volts. |
• | The scan tool special functions are not active. |
• | The HO2S Sensor 1 Heater command parameter is ON. |
• | The Engine Run Time parameter is more than 2 minutes. |
P0140 - Regular Test
• | DTCs P0036, P0054, P0068, P0101, P0102, P0103, P0107, P0108, P0112, P0113, P0116, P0117, P0118, P0120, P0121, P0122, P0123, P0128, P0201, P0202, P0203, P0204, P0205, P0206, P0220, P0222, P0223, P0442, P0443, P0446, P0449, P0451, P0452, P0453,
P0454, P0455, P0496, P1516, P2101, P2119, P2135, P2176 are not set. |
• | The system voltage is between 10-18 volts. |
• | The scan tool special functions are not active. |
• | The Engine Run Time parameter is more than 2 minutes. |
• | The TP Indicated Angle parameter has changed more than 5 percent at least 3 times. |
• | The Loop Status parameter is closed. |
P0140 - Fast Pass Test
• | DTCs P0036, P0054, P0068, P0101, P0102, P0103, P0107, P0108, P0112, P0113, P0116, P0117, P0118, P0120, P0121, P0122, P0123, P0128, P0201, P0202, P0203, P0204, P0205, P0206, P0220, P0222, P0223, P0442, P0443, P0446, P0449, P0451, P0452, P0453,
P0454, P0455, P0496, P1516, P2101, P2119, P2135, P2176 are not set. |
• | The system voltage is between 10-18 volts. |
• | The scan tool special functions are not active. |
• | The Engine Run Time parameter is less than 90 seconds. |
P1133 and P1134
• | DTCs P0030, P0053, P0068, P0101, P0102, P0103, P0107, P0108, P0112, P0113, P0116, P0117, P0118, P0120, P0121, P0122, P0123, P0128, P0131, P0132, P0134, P0135, P0201, P0202, P0203, P0204, P0205, P0206, P0220, P0222, P0223, P0300, P0442, P0443,
P0446, P0449, P0451, P0452, P0454, P0455, P0496, P1516, P2101, P2119, P2135, P2176, P2A00 are not set. |
• | The system voltage is between 10-18 volts. |
• | The scan tool special functions are not active. |
• | The HO2S Sensor 1 Heater command parameter is ON. |
• | The ECT Sensor parameter is more than 65°C (149°F). |
• | The Engine Run Time parameter is at least 60 seconds. |
• | The EVAP purge solenoid is commanded ON. |
• | The MAF sensor parameter is between 15-30 g/s. |
• | The Engine Speed parameter is between 1,300-3,000 RPM. |
• | The TP Indicated Angle parameter is greater than 3.5 percent. |
• | The Loop Status parameter is closed. |
• | The BARO parameter is at least 69.8 kPa. |
• | The vehicle is not in Park, Reverse, or Neutral. |
• | The above conditions have been met for 1 second. |
P2A00
• | DTCs P0030, P0053, P0068, P0101, P0102, P0103, P0107, P0108, P0112, P0113, P0117, P0118, P0120, P0121, P0122, P0123, P0128, P0131, P0132, P0133, P0134, P0135, P0151, P0152, P0153, P0154, P0201, P0202, P0203, P0204, P0205, P0206, P0220, P0222,
P0223, P0442, P0443, P0446, P0449, P0451, P0452, P0453, P0454, P0455, P0496, P1133, P1153, P1516, P2101, P2119, P2120, P2122, P2123, P2135, P2176, P2A03 are not set. |
• | The Engine Run Time parameter is more than 100 seconds. |
• | The MAF Sensor parameter is between 5-30 g/s. |
• | The Engine Speed parameter is between 500-3,000 RPM. |
• | The TP Indicated Angle parameter is between 3-35 percent. |
• | The ECT Sensor parameter is more than 65°C (149°F). |
• | The Ignition 1 Signal parameter is between 10-18 volts. |
• | DTC P2A00 runs continuously when the above conditions are met for 5 seconds. |
P2A01 - Passive Test
• | DTCs P0030, P0053, P0068, P0101, P0102, P0103, P0107, P0108, P0112, P0113, P0117, P0118, P0120, P0121, P0122, P0123, P0128, P0131, P0132, P0133, P0134, P0135, P0171, P0172, P0174, P0175, P0201, P0202, P0203, P0204, P0205, P0206, P0220, P0222,
P0223, P0442, P0443, P0446, P0449, P0451, P0452, P0453, P0454, P0455, P0496, P1133, P1516, P2101, P2119, P2135, P2176, P2A00 are not set. |
• | The engine is running for at least 5 minutes. |
• | The ignition voltage is between 10-18 volts. |
P2A01 - Intrusive Test
• | DTCs P0030, P0053, P0068, P0101, P0102, P0103, P0107, P0108, P0112, P0113, P0117, P0118, P0120, P0121, P0122, P0123, P0128, P0131, P0132, P0133, P0134, P0135, P0171, P0172, P0174, P0175, P0201, P0202, P0203, P0204, P0205, P0206, P0220, P0222,
P0223, P0442, P0443, P0446, P0449, P0451, P0452, P0453, P0454, P0455, P0496, P1133, P1516, P2101, P2119, P2135, P2176, P2A00 are not set. |
• | The Engine Run Time parameter is more than 5 minutes. |
• | The ignition voltage is between 10-18 volts. |
• | The Engine Speed parameter is between 625-1,750 RPM. |
• | The MAF Sensor parameter is between 4-15 g/s. |
• | The Vehicle Speed parameter is between 40-132 km/h (25-82 mph). |
• | When all of the above conditions have been met for at least 2 seconds, the following conditions must also be met: |
- | The evaporative emission (EVAP) purge diagnostic is not active. |
- | The Short Term FT parameter is between +5 and -5 percent. |
- | The Loop Status parameter is closed. |
Conditions for Setting the DTC
P0133
• | The control module detects that the HO2S 1 rich-to-lean and lean-to-rich transition time takes longer than a calibrated value. |
• | This diagnostic runs once per trip. |
P0134
• | The control module detects that the HO2S 1 signal voltage is between 382-525 mV for more than 30 seconds. |
• | This diagnostic runs continuously. |
P0140 - Fast Pass Test
During the fast pass, the HO2S 2 voltage is between 382-525 mV for longer than 18 seconds within the first 90 seconds of engine run time. If the fast pass test does not report a pass, then the regular test is initiated.
P0140 - Regular Test
• | During the regular test, the HO2S 2 voltage is between 390-520 mV for at least 120 seconds. |
• | This diagnostic runs once per trip. |
P1133 and P1134
• | The control module detects that the HO2S 1 voltage did not have enough switches from rich-to-lean and lean-to-rich during a 90 second monitoring period. |
• | This diagnostic runs once per trip. |
P2A00
• | The control module detects that the HO2S 1 voltage signal remains within the 300-600 mV range for more than 10 seconds. |
• | This diagnostic runs continuously. |
P2A01
• | The HO2S 2 parameter is between 250-775 mV during the passive test. |
• | One of the following tests fail: |
Lean Intrusive Test
- | The control module detects that the HO2S 2 voltage is more than 250 mV . |
- | The control module detects that the HO2S 1 voltage is less than 100 mV. |
Rich Intrusive Test
- | The control module detects that the HO2S 2 voltage is less than 775 mV. |
- | The control module detects that the HO2S 1 voltage is more than 825 mV. |
• | This diagnostic runs once per trip. |
Action Taken When the DTC Sets
DTCs P0133, P0134, P0140, P1133, P1134, P2A00, and P2A01 are Type B DTCs.
Conditions for Clearing the MIL/DTC
DTCs P0133, P0134, P0140, P1133, P1134, P2A00, and P2A01 are Type B DTCs.
Reference Information
Schematic Reference
Engine Controls Schematics
Connector End View Reference
Electrical Information Reference
DTC Type Reference
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Scan Tool Reference
Circuit/System Verification
- If any HO2S heater DTCs are set, perform those diagnostics first.
- Allow the engine to reach operating temperature.
- Engine running, observe the affected HO2S parameter with a scan tool.
⇒ | The pre-catalyst oxygen sensor value should vary from below 200 mV to above 800 mV and respond to fueling changes. |
⇒ | The post-catalyst oxygen sensor value should change more than 200 mV
when the throttle is quickly cycled 3 times from closed to wide open and back to closed after running the engine at 1,500 RPM for 30 seconds. |
- The affected HO2S may be damaged due to contamination. Prior to replacing the affected HO2S, inspect for the following sources of contamination.
Notice: Refer to Silicon Contamination of Heated Oxygen Sensors Notice in the Preface section.
• | A silicon contaminated HO2S |
Circuit/System Testing
Important: All modules must be powered down or misdiagnosis may result.
- Ignition OFF, disconnect the scan tool and wait 60 seconds to ensure all modules are powered down.
- Ignition OFF, disconnect the harness connector at the appropriate HO2S.
- Ignition OFF, measure for less than 5 ohms resistance between the appropriate HO2S low signal circuit terminal A and ground.
⇒ | If more than the specified range, test the appropriate HO2S low signal circuit for an open/high resistance. If the circuit tests normal, replace the ECM. |
- Ignition ON, verify the appropriate scan tool HO2S parameter is approximately 450 mV.
⇒ | If more than the specified value, test the appropriate HO2S high signal circuit for a short to voltage. If the circuit tests normal, replace the ECM. |
⇒ | If less than the specified value, test the appropriate HO2S high
signal circuit for a short to ground. If the circuit tests normal, replace the ECM. |
- Ignition ON, install a 3A fused jumper wire at the HO2S high signal circuit terminal B. Toggle the jumper wire between the HO2S low signal circuit terminal A and battery voltage. Verify the appropriate scan tool HO2S parameter
toggles between 0 mV and approximately 1,000 mV.
⇒ | If the appropriate scan tool HO2S parameter does not toggle correctly, test the HO2S high signal circuit for an open/high resistance. If the circuits test normal, replace the ECM. |
- If all circuits test normal, replace the appropriate HO2S.
Repair Instructions
Notice: Refer to Heated Oxygen Sensor Resistance Learn Reset Notice in the Preface section.
Perform the
Diagnostic Repair Verification
after completing the diagnostic procedure.