Removal Procedure
- Remove the left closeout panel. Refer to
Instrument Panel Insulator Panel Replacement - Left Side.
- Disconnect the electrical connector from the left air temperature actuator.
- Remove the mounting screws from the left air temperature actuator.
- Remove the left air temperature actuator.
Installation Procedure
- Position the left air temperature actuator. Align the slots in the electric actuator driver to the flats on the shaft.
- Align the locating hole to the alignment pin on the HVAC module case.
- Slide the actuator on the shaft. The actuator driver should seat completely onto the shaft and the mounting holes should be flush with the mounting screws on the HVAC module case.
Notice: Refer to Fastener Notice in the Preface section.
- Install the mounting screws to the left air temperature actuator.
Tighten
Tighten the screws to 1.5 N·m (13 lb in).
- Connect the electrical connector to the left air temperature actuator.
- Install the left closeout panel. Refer to
Instrument Panel Insulator Panel Replacement - Left Side.
- Calibrate the actuator. Refer to
Actuator Recalibration.